Backup Templates
----------------

The following files are installed in case there is a firmware 
corruption. IF the RST100, RST200, RST300, or RST310 has all the 
display leds on then it is expecting a firmware download. If the 
BMS can connect to the RST then it not NOT recommended that these 
files are used.

Install Flashmagic
-------------------
Run the file flashmagic.exe, follow the prompts and install flashmagic
to your pc.

Restart your PC after the install has completed.


Batch Files.
------------
*.bat
Double click on the approriate file to state set the firmware.


Configuration files.
--------------------
*.dat
These files are use to configure the download procedure.

The "COM(1,19200)" will need to be adjusted if there the RST
is configured not configured on COM1. For example if com port 4
is used the line should read "COM(4,19200)".


Firmware Files.
---------------
*.hex

The firmware files. The current version of firmware is 3.6 for
RST100, RST200, RST300, or RST310 models and the current firmware 
version for the RST03x models is 1.4.


Instructions.
-------------
Copy the "backup" from the CD (if applicable) to a 
local drive.

Check that the RST is in program mode.
- RST100/RST200/RST300/RST310 all LEDs on, or
- RST03x Red LED is on
If the RST is not in program mode then there is no need
to continue and the BMS should be used to update the firmware.

Change and save the configuration file to point to the correct 
PC com port. This may need to be tested by trial and error.
Serial ports are likely to be 1-4 and USB converted ports are
likely to be 3-8.  Each time an attempt is made to program the
RST power cycle the unit.

Power cycle the unit.

Double click on flashXXX.bat to start the firmware upload.
Programming will take up to 3 minutes, and the terminal will
automatically reboot once ready.

Successful Flash Magic Messages.
--------------------------------
C:\Temp\Beam\Backup>FM @RST03x.DAT

Flash Magic Version 1.76
(DLL Version 1.47)
(C) Embedded Systems Academy 2000-2003 All rights reserved
Connected
Device selected
High Speed mode selected
Hex file programming complete (RST03x.HEX)
....